Service, Servicing from the outside of the house – Montigo PVHFL58-300 User Manual
Page 10
Advertising
Service
Page 10
XG0519 - 070714
Step 3: Remove the louver assembly by lifting the bottom end forward and
then dropping the door out of the top latches.
Figure 5a.
Step 4: Remove the three screws securing the rain guard.
Figure 5.
Figure 5b.
Go to Capacitor or Motor and Capacitor Replacement Section.
PVHFL58-300 & PVHFL510-300 Horizontal Power Vent
Servicing
From the outside of the house
Step 1: Turn off gas and power.
Step 2: Remove two screws from the bottom of the louver assembly.
Caution: Hold the louver assembly securely so it does not fall.
Advertising