Page 19

XG0519 - 070714

Go to reinstalling either from outside or inside.

PVHFL58-300 & PVHFL510-300 Horizontal Power Vent

Step 13: Using the other supplied small bell connector, connect the brown

wire from the motor to the black wire of the capacitor.

Figure 10m.

Step 14: Secure the wiring neatly with the supplied zap straps. Check that

the power vent operates and spins counterclockwise. NOTE: When replacing

from inside you will need to reinstall the power vent and check spin from the

outside. Note: Ensure wires are secured away from moving parts

Figure 10n.

Step 12: Using the other supplied large bell connector, connect the white

fibre wire from the power cable to the black wire from the capacitor and the

black wire from the motor.

Figure 10l.