Installation, Finishing around the fireplace – Montigo C34DV User Manual

Page 12

Advertising
background image

Page 12

C-Series DV Gas Fireplace

Part No. XG0170 - 080610

Installation

Finishing Around the Fireplace

Combustible mantels and mouldings may be safely installed over the

top and on the front of the fireplace provided that they do not project

beyond shaded area shown in Figure's 24 & 24a.
Side wall clearances are 3". Combustible surrounds may be installed

with 3" clearance to the side of the fireplace as shown in Figure 25.

Fireplace Facing

When selecting the finish material for your fireplace, it is important to

remember the following: THE HORIZONTAL LOUVRES MUST NOT

BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply

for the control compartments and heat exchanger it also prevents

access for servicing controls.
The face of the fireplace may be painted to match the room decor,

provided you use a heat-resistant paint. Decorative facing must not

extend past the fireplace opening at all, because it will interfere with

the access to retainers for removal of glass door.

Mantels & Surrounds

NOTE: National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the

wise use of energy, has prompted us to manufacture many models of

fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal

room temperature and walls above fireplace may be hot to touch.
Warning:
When covering the upper metal portion of the fireplace with a non-

combustible material Please Note: The decorative facing materials

may be subject to temperatures in excess of 250° F. This should be

considered when selecting facing materials.
We recommend careful consideration be given to the effects of elevated

mantel temperatures which may be in excess of product design, for

example: candles, plastic or pictures. This can cause melting, deformation,

discoloration or premature failure of T.V. and radio components.

Painting:

Special care is recommended by the Master Painters and Decorators

Association, when painting the fireplace surrounds, to select and apply

a quality Alkyd sealer prior to the applying of latex paints. This is to

prevent leaching of water from evaporation and causing a brownish

staining effect to paint over coats.

Figure 25. Combustible surrounds.

Figure 24. Combustible mantles and facings for C34DV.

Figure 24a. Combustible mantles and facings for C38DV.

C34DV

C38DV

Advertising
This manual is related to the following products: