C-Series DV Gas Fireplace

Part No. XG0170 - 080610

Introduction

Thank You for choosing a Montigo Gas Fireplace.

About this Fireplace:

The C-Series DV is a dual burner fireplace with glowing embers and

five piece ceramic fibre logset. The fireplace is available in two models,

and in top or rear vent for each model.

Standard Log Set

The C34DV is rated for Natural Gas at 20,000 BTU/H (5.86

Kilowatts) Input or Propane at 20,000 BTU/H (5.86 Kilowatts) Input.

Q

C34DT; Top Vent, Millivolt Pilot.

Q

C34DR; Rear Vent, Millivolt Pilot.

Q

C34DT-I; Top Vent, Intermittent Pilot (HSI).

Q

C34DR-I; Rear Vent, Intermittent Pilot (HSI).

Q

C34DT-F; Top Vent, Electronic Ignition (IPI).

Q

C34DR-F; Rear Vent, Electronic Ignition (IPI).

Standard Log Set

The C38DV is rated for Natural Gas at 25,000 BTU/H (7.32

Kilowatts) Input or Propane at 25,000 BTU/H (7.32 Kilowatts) Input.

Q

C38DT; Top Vent, Millivolt Pilot.

Q

C38DR; Rear Vent, Millivolt Pilot.

Q

C38DT-I; Top Vent, Intermittent Pilot (HSI).

Q

C38DR-I; Rear Vent, Intermittent Pilot (HSI).

Q

C38DT-F; Top Vent, Electronic Ignition (IPI).

Q

C38DR-F; Rear Vent, Electronic Ignition (IPI).

How to use this manual:

This manual covers installation, operation and maintenance. Lighting,

operation and care of this fireplace can be easily performed by the

homeowner. However, all installation and service work should be

performed by a qualified or licensed installer, plumber, or gasfitter who

is qualified or licensed by the state, province, region, or governing body

in which the appliance is being installed.
This manual covers all models and unless otherwise specified, the

designation C-Series DV refers to all models. Sections which are

specific to a particular model are marked with a

symbol, plus the

appropriate model number.

CAUTION!

Due to its high operating temperatures, the appliance should
be located out of traffic & away from furniture and draperies.

Children and adults should be alerted to the hazards

of the high surface temperature, which could cause
burns or clothing ignition.

Young children should be carefully supervised when

they are in the same room as the appliance.

Clothing or other flammable materials should not be

placed on or near the appliance.

Warranty and Installation Information:

The Montigo warranty will be voided by, and Montigo disclaims any

responsibility for, the following actions:

Q

Modification of the fireplace and/or components including Direct-

Vent assembly or glass doors.

Q

Use of any component part not manufactured or approved by

Montigo in combination with this Montigo fireplace system.

Q

Installation other than as instructed in this manual.

Consult your local Gas Inspection Branch on installation requirements

for factory-built gas fireplaces. Installation & repairs should be done by

a qualified contractor.
Installations in Canada must conform to the current CAN/CGA B-149.1

and .2 Gas Installation Code and local regulations. If the optional air-

circulating fan kit is installed, it must be electrically grounded in accordance

with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must conform to local codes, or in the absence

of local codes to the National Fuel Gas Code, ANSI Z223.1-1988. If the

optional air-circulating fan is installed, it must be grounded in accordance

with local codes or, in the absence of local codes, with the National

Electrical Code, ANSI/NFPA 70-1987. See Appendix B for installation

within the State of Massachusetts.accordance with local codes or, in

the absence of local codes, with the National Electrical Code, ANSI/

NFPA 70-1987.
See Appendix B
for installation within the State of Massachusetts.

WARNING

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER

ALLOW CHILDREN

TO TOUCH GLASS.

Advertising