Installation

Installing and Framing the Fireplace

The fireplace may be installed in any location that maintains proper clear-

ances to air conditioning ducts, electrical wiring and plumbing. Safety,

as well as efficiency of operation, must be considered when selecting

the fireplace location. Try to select a location that does not interfere

with room traffic, has adequate ventilation, and offers an accessible

pathway for Direct Vent installation. Refer to page 4 - Vent Installation

for more information.
The fireplace dimensions are shown below:

When installing a shelf over the top of the fireplace, the following

guidelines must be adhered to: For Rear Vent applications the

minimum clearance from the top of the fireplace to a shelf is 6 1/2". For

Top Vent applications, the minimum clearance is 13 1/2". (Minimum

2" clearance must still be maintained around the vent pipes.)

Figure 4. Framing for shelves over the fireplace.

Top Vent

Figure 3. Minimum Corner framing dimensions, using a 45° elbow.

Figure 2. Framing dimensions.

* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8"

Framing

Top View

Front View

Side View

* Clearance from the top of the fireplace to a combustible ceiling

within the fireplace enclosure.
** Refer to graph and requirements on Page 11.
Unprotected combustible walls which are perpendicular to the fireplace

opening, must not project beyond the shaded area shown in Figure 25.
For protection against freezing temperatures, it is recommended that

outer walls of the chase be insulated with a vapor barrier. This will reduce

the possibility of a cold-air convection current on the fireplace.

Figure 1. Fireplace dimensions.

Rear Vent

(On Applicable Models)

M

N

O

N P

Q

2" clearance

to corners only

M

N

O

N P

Q

2" clearance

to corners only

M

N

O

N P

Q

2" clearance

to corners only

M

N

O

N P

Q

2" clearance

to corners only

M

N

O

N P

Q

2" clearance

to corners only

WARNING!

When this appliance is installed directly on any combustible mate-

rial other than wood flooring, it must be installed on a metal or

wood panel extending the full width and depth of the appliance.

M

T

6 1/2

S

13 1/2

Framing / Header,

shelf

L

M

MEL Short

90 elbow

shelf

Framing/ Header

Clearances

These clearances apply to all dimensions except the framed opening,

where the clearance to combustibles is 0". The C-Series DV clearances

to combustible materials are:

M N O P Q R T

C34-DV

36

3

/

4

33

14

1

/

2

50

35

3

/

8

30

3

/

8

39

7

/

8

C38-DV

39

3

/

4

37

17

5

/

8

56

39

5

/

8

33

3

/

8

42

7

/

8

C42-DV

44

41

1

/

4

18

61

3

/

8

43

3

/

8

37

5

/

8

47

1

/

8

C34-DV C38-DV

Top - Rear Vent *

6 1/2"

6 1/2"

Top - Top Vent

13 1/2"

13 1/2"

Back

0"

1"

Sides

1"

0"

Floor

0"

0"

Mantle**

6"

8"

C34-DV 33

3

/

4

31

1

/

2

31 1

1

/

4

18 1

3

/

4

21

3

/

4

8 5 8 25

1

/

4

C38-DV 37

3

/

4

34

1

/

2

34

3

/

4

1

1

/

4

21 1

7

/

8

24

1

/

8

9 5 8 28

3

/

8

C42-DV

42 38

3

/

4

38

3

/

4

1

1

/

4

24

1

/

2

11 6

3

/

4

27

7

/

8

10

1

/

4

58

32

1

/

2

A B C D E F G H I J K L

11

15

Advertising
This manual is related to the following products: