M38DV-PFC Peninsula Gas Fireplace

Maintenance

HONEYWELL SV 9500 /SV9600

Troubleshooting Sequence

NOTE:

Before Troubleshooting, Familiarize Yourself With

The Startup And Checkout Procedure.

· TurnGasSupplyoff
· Setthermostatto

call forheat

SV9500/SV9600
ispowered
(24VACnominal)

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

NO

NO

NO

START

Igniterwarmsup
andglowsred.

PilotValveopens.

Turngason.
PilotBurnerlights?

MainValveopens?

SYSTEMOK

UnplugPilotBurnerCable,
MeasureVoltageat
SV9500/SV9600HSI
Terminals(24VAC
Nominal, SeeINSET)

ReplaceIgniter/
FlameRodAssembly.

ReplaceIgniter/
FlameRodAssembly.

ReplaceSV9500/SV9600

MeasureVoltagetoSV9500
/SV9600. Voltagemust
beatleast19.5VAC

DiscardoldIgniter/
FlameRodAssembly.

ReplaceIgniter/Flame
RodAssemblyandretain.
RestartTroubleshooting
Sequence. Doesmain
valveopen?

Replace
SV9500/
SV9600

Check
Transformer
LineVolt
Supply

Replace
SV9500/
SV9600.
Saveold
Igniter/Flame
RodAssembly
forservice.

INSET

HSI

Terminals

CHECK:

· Linevoltagepower

· Lowvoltage transformer

· LimitController

· Thermostat

· Wiring

· Airprovingswitchon

combustionairblowersystem

· Ventdamper(ifused) isopen

andendswitchmade

Troubleshooting

If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified
agency.
All spare parts, optional fans (see optional fan instruction guide), and
optional trim finishes are available from Canadian Heating Products
Inc. or your local dealer.

M38DV-PFC-I

Troubleshooting

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE ACTION

Noisy Pilot Flame

Locate pilot adjustment screw on the
front of the gas control valve. Flame
is decreased by turning adjustment
screw clockwise.

Pilot won’t ignite

Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram

figure

19.

Main burner will

1. Check wiring (see figure 19)

not light

2. Check wall switch for proper con-
nection.

3. Check pilot burner. If extinguished:

a. Allow fireplace to cool, then try to
relight.

b. If condition persists, call a qualified
service person.