M38DV-PFC Peninsula Gas Fireplace

Installation

Vertical Vent Installations

Vertical Terminations must be installed:

minimum 2' (two feet) above the highest point where

vent passes through the roof.

minimum 6' (six feet) from a mechanical air inlet

minimum 3' (three feet) from a parapet wall.

Maximum vent height is 30 feet above fireplace.

Note: Flame characteristics will change if the maximum vent

height is used.

Minimum clearances 2" from vent to all combustible materials

must be maintained.

A maximum of two offsets with 45° bends may be made if the length
of the offsets does not exceed 25% of the vertical vent height, when
measured center to center of piping.

Example:

Typical vent installation.

30' vertical vent

2 - 2' offsets required

25% of 30' = 7-1/2' max. offset allowed

This venting configuration meets requirements.

A - Termination

PVTK-1

B - Flex sections

PFL-1 (12" section)

PFL-2 (24" section)

PFL-3 (36" section)

PFL-4 (48" section)

C - Solid sections

PEXT-1 (12" section)

PEXT-2 (24" section)

PEXT-3 (36" section)

PEXT-4 (48" section)

PEXT-6 (72" Section)

D - Support Ring & Plate

PSPXT-7 (8" dia.)

E - Firestop

PS-8 (8" dia.)

F - Roof Flashing

PRF-7 (1/12 - 7/12 pitch)

PRF-12 (7/12 - 12/12 pt.)

PRF-16 (12/12 - 16/12 pt.)

Figure 10.

Straight, vertical venting. The elbow shown is a PEL-90F/

F, which is connected directly to the fireplace flue collar.

No special adaptor is required.

Storm collar

PEXT

Solid Section

Roof flashing

30' max.

* Minimum 2" clearance to all combustibles

Firestop

Firestop

2' min.

90° Elbow (F/F)

Support plate

Support ring

2' min.

Storm collar

Support ring

Roof flashing

30' max.

* Minimum 2" clearance to all combustibles

Support plate

Firestop

PVA Adaptor

90° Elbow

2' min.

2'

Storm collar

Roof flashing

30' max.

* Minimum 2" clearance to all combustibles

Support straps or
support plate & ring

Firestop

Firestop

Firestop

Support plate
& ring

PVA Adaptor

90° Elbow

Figure 12.

Typical vertical venting application application 2 offsets.

Figure 11.

Typical vertical venting application using 1 offset.

Advertising