Installation

Installing The Fireplace Shell

The fireplace may be installed in any location that is free of air con-
ditioning ducts, electrical wiring and plumbing. Safety, as well as ef-
ficiency of operation, must be considered when selecting the fireplace
location. Try to select a location that does not interfere with room
traffic, has adequate ventilation, and offers an accessible pathway for
Direct Vent installation.
The fireplace dimensions are shown below:

Figure 1.

Fireplace dimensions.

Framing

Unprotected combustible walls which are perpendicular to the
fireplace opening, must not project beyond the shaded area shown in
Figure 19b.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.

End View

WARNING

:

When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.

Side View

23

35 3/4

38

Figure 2.

Framing dimensions. Clearance between the top of the

fireplace and the header may be 0", but we recommend a

clearance of 1/2" - 1" to allow for settling of the building.

Clearances

The M38DV-PFC clearances to combustible materials are:

Top*

0"

Back

0"

Floor

0"

Mantle**

6"

Flue

1"

* Clearance from the top of the fireplace to

a combustible ceiling within the fireplace
enclosure.

** Refer to page 8.

34 5/8

27 3/4

28 1/2

38 1/2

24 5/8

1 1/2

13 3/4

16 1/4

3

3 1/2