Page 

P/N XG0202

M38DV-PFC Peninsula Gas Fireplace

Installation

Wiring

115/1/60 Supply

G

L1 L2

Figure 15b.

Fan wiring schematic.

Gas Control and Pilot Wiring

Honeywell (Q3450)
Pilot Assembly

Pilot Electrical

Harness Connector

Honeywell Gas

Control (SV9501M)

Gas Control

Connector

Fuse

Limit

Switch

Wall

Switch

Fan Plug

Receptacle

Junction Box

Junction Box Cover

White

Black

Green

40 VA

Transformer

115VAC

24VAC

Grnd Screw

Figure 14.

Wiring for the M38DV-PFC-I with Honeywell gas control

and pilot.

Figure 15a.

Fan wiring.

NOTE:

If any of the original wire supplied with the appli-
ance is replaced, it must be replaced with the same
type, or its equivalent.

Fan Wiring

The M38DV-PFC is equipped with 3 fans for circulating heat into the
living space. Installations in Canada must be in accordance with
CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must be in accordance with local codes

or, in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-1987.

G

L1-WH

L2-BLK

Quick Connect

plug to motor

Fan Switch

Fan Switch

Fan

Motors

(3)

M38DV-PFC-I

Figure 16b.

Completed Installation.

Figure 16a.

Log Installation.

Installing the Logs and Embers

Bottom Logs

The M38DV-PFC is supplied with five (5) fibre logs. The two large

bottom logs (logs

"A" and "B") are mounted on the burner grate by

placing them into the slots.

Top Logs

Place logs

"C" and "D" into their mating positions on the large logs as

shown in Figure 16a below. Log

"E" is mounted on top of logs "C" and

"D" as shown in Figure 16b.

WARNING: If logs are not placed properly, excessive

sooting will result.