Installation overview, Tuscany, Clearances – Montigo 34DVI Tuscany User Manual

Page 4: Inspecting & cleaning the chimney

Advertising
background image

Page 4

Tuscany

Gas Fireplace Insert

P/N XG0515

Installation Overview

Before You Begin

ensure that your masonry fireplace's opening is large enough to

accommodate the Tuscany. The insert's dimensions are shown below

Top View

Side View

Note: Minimum masonry fireplace depth = 16"

Front View with Sunrise Faceplate Willow Faceplate height

Figure 1: Fireplace dimensions

clearances

The tuscany clearances to combustible materials are:
* Refer to figure 2

.Unprotected combustible walls which are perpendicular to the fireplace

opening, must not be closer than 3" to the faceplate.
The Tuscany must be installed in a masonry or factory-built solid fuel

fireplace with a hearth extending 16" from the fireplace facing.

Inspecting & cleaning the chimney

The chimney must be built in accordance with the Standards for

Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances,

NFPA-211 or applicable National, Provincial, state or local codes.

Inspect the chimney where the insert will be installed. ensure

that it is in good condition and has been properly constructed

according to your local code. Check the outside of the chimney

and masonry for damage including cracked, loose or damaged

bricks and mortar, or other materials that could inhibit the correct

installation of the flexible chimney liner. ensure that any damage

or deterioration has been properly repaired.

Remove any glazed creosote that has built-up inside the chimney.

The existing passageway must be cleared of any obstructions

that would prevent the flex liner installation.

The flex liner does not require any clearance between the flex

liner and the inner masonry wall. However it is recommended

that there be at least 1/2" clearance to fit the flex liner down the

chimney.

Note: The existing fireplace damper should be locked open.

If the opening is too small for two 3" liners, then the damper

should be removed.

The appliance has gas access holes on the right and left hand

side. The easiest point of instillation is on the left side of the

fireplace and is supplied with a flexible gas connector which

extends out either side of the insert a few inches (See figure

3). A 1/2" gas supply pipe must be brought near this connection

before installing the Tuscany insert.

Figure 2: Mantle Clearances.

Perpendicular Wall

3"

Floor

Non-combustable

Mantle (10" wide)*

18 1/2"

27

7/8

20

1/2

9

1/4

17” 15

1/2

18

1/4

” 20

1/4

4

39 3/4

27 1/4

25 5/8

27 3/

12 1/4

26

Advertising