Tuscany, Installing the gas line, Chimney liner installation – Montigo 34DVI Tuscany User Manual

Page 5

Advertising
background image

P/N XG0515

Page 5

Tuscany

Gas Fireplace Insert

Installation Section 1

nOTE:

After the gas line is connected, each appliance connection,

valve and valve train must be checked while under normal

operating pressure with either a liquid solution, or leak

detection device, to locate any source of leak. Tighten any

areas where bubbling appears or leak is detected until

bubbling stops completely or leak is no longer detected. Do

not use a flame of any kind to test for leaks.

Installing The Gas Line

Before installing the insert, ensure gas line is brought to close proximity

of the unit. For ease of installation, this appliance is equipped with an

approved flexible gas connector. The connector is factory-installed and

can be connected to the gas line as shown in figure 3.

DO nOT

cOnnEcT THE GAS LInE YET.

Note that the gas connection is on the right side of the unit.

Attach the gas line to the flexible gas connector with an approved fitting,

as required by the

applicable installation codes.

Only use gas shut-off valves approved for use by the state,

province, region, or governing body, in which the appliance

is being installed, or as required by the applicable installation

codes.

natural Gas

requires a minimum inlet gas supply pressure of 5.5"

W.C. & a manifold pressure of 3.5" W.C.

Propane Gas

requires a minimum inlet gas supply pressure of 11"

W.C. and a manifold pressure of 10" W.C. The fireplace gas connection

and the main operating gas control valve is located underneath the

firebox in the control compartment.
The appliance and its individual shutoff valve must be disconnected

from the gas supply piping system during any pressure testing of that

system at test pressures in excess of 1/2 psig (3.5 kPa)
The appliance must be isolated from the gas supply piping system by

closing its individual manual shutoff valve during any pressure testing

of the gas supply piping system at test pressures equal to or less than

1/2 psig (3.5 kPa)

Figure 3. Gas line location on the right-hand side of the appliance

(similar on both sides)

chimney Liner Installation

This appliance is approved for installation only with DelRay's Direct

Vent flex liner kit (part# VT35DV3). The kit contains two 3" diameter

flex liners, a Direct Vent chimney cap, and a 16" by 16" flashing.
All installations must conform with local codes. In the absence of local

codes, installations must conform with the most recent version of the

American National Fuel Gas Code

(AnSI Z223.1-1988)

or the

Canadian Gas Installation Code (

cAn/cGA B149.1 and .2)

.

STEP 1:

Determine the length of the vent run in the masonry

chimney. Measure from the masonry base of the fireplace

to the top of the clay liner and allow an extra 18" for fitting

to the fireplace.

STEP 2:

Stretch the flex liner to the desired length. Or, if necessary,

cut the flex liner to the measured length using snips, a

hacksaw, or a disc cutter. Remember to

allow an extra

18" for fitting

to the fireplace.

Note: Mark one of the pipes for air intake and one for exhaust

outlet, to ensure that the proper connections will be made.

Figure 4: Direct Vent System