How to determine the available straight pipe run – ONICON F-5200 Inline User Manual

Page 10

Advertising
background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-5200 Inline Thermal Mass Flow Meter Manual 05/14 - 0763-4 / 19476

Page

10

EVALUATING UPSTREAM

PIPING CONDITIONS

Straight Pipe

Single Bend

Pipe Reduction

Multiple Bends in Same Plane

Pipe Expansions

Tees

Multiple Bends Out of Plane

Modulating or Regulating Valve

W

orse

Better

In addition to the information provided on the previous page,
the diagrams and the table shown below should be used as a
guide to identifying the best installation location for the meter.

Required upstream/downstream distances in inches as
measured from the process connections.

9" Minimum

Height

Upstream

Downstream

Available Straight Run

Upstream

Downstream

9"Minimum Height

Meter may be installed in a

vertical pipe with upward or

downward flow

Meter may be installed on

the bottom of horizontal

pipes.

Flow

Flow

Flow

FLOW DIRECTION

FLOW DIRECTION

FLOW DIRECTION

Flow

FLOW DIRECTION

How to Determine the Available Straight Pipe Run:

Locate the longest straight unobstructed section of pipe available. To be unobstructed, the section of

pipe must be free of bends, tees, size transitions, valves or insertion probes of any kind.


3.

If there is insufficient straight run, allow 80% of the run upstream and 20% of

the run downstream. If the total length of straight run is less than 75% of the

recommended distance, performance may seriously degrade.

Minimum Straight Run required upstream of flow meter process connection based on the nature of the upstream obstruction.

Minimum

Downstream

Straight Run

Required After

Flow Meter

Process

Connection

Upstream

Obstructions

Single bend preceded by ≥

9 diameters of straight pipe

Or

Pipe size reduction in

straight pipe run

Multiple bends in plane with

< 9 diameters of straight

pipe between them

Or

Pipe size expansion in

straight pipe run

Tees

Multiple bends

out of plane

Modulating or

Regulating valves

Or

Roots or Diaphram

Utility Meters

Nom. Dia.

¼”

None

2.5”

2.5”

2.5”

2.5”

None

⅜”

1.25”

3.75”

3.75”

3.75”

3.75”

None

½”

1.5”

5”

5”

5”

5”

None

¾”

2.25”

7.5”

7.5”

7.5”

7.5”

1”

1”

3”

10”

10”

10”

10”

1”

1¼”

3.75”

12.5”

12.5”

12.5”

12.5”

2”

1½”

4.5”

15”

15”

15”

15”

2”

2”

6”

20”

20”

20”

20”

4”

2½”

7.5”

25”

25”

25”

25”

7”

3”

9”

30”

30”

30”

30”

9”

4”

12”

40”

40”

40”

40”

12”