SECTION 2.0: UNPACKING

ONICON Insertion Thermal Mass Flow Meters are packed and shipped in individual cartons.
An optional installation hardware kit, if ordered, will be packaged with each meter. All other
installation hardware and peripheral devices, including flow conditioners, will be packaged and
shipped separately.

Please open all packages with care to prevent damage to their contents. Carefully inspect each
item for signs of damage in transit. The flow meter stem should be straight and free of blemishes or
abrasions.

All ONICON products are shipped insured unless the customer specifically requests otherwise. Please
notify the shipping company and ONICON immediately if any items are damaged in transit. Save all
packing material for inspection by the shipper.

2.1 CHECKING THAT YOU RECEIVED EVERYTHING

Standard Documentation

Enclosed with each meter is a comprehensive documentation package that includes the

following items:


• Installation and Operation Guide

• Flow Meter Calibration Certificate

• Product Data Sheet

Please notify the ONICON customer service department if any of these documents are

missing.

Product

• F-5200 Insertion Thermal Mass Flow Meter

• Optional Installation Hardware Kit, if ordered

SECTION 3.0: INSTALLATION, REMOVAL AND ADJUSTMENT

WARNING

Insertion flow meters may be installed in pipes which are under high pressure or pipes filled with

combustible gases. Accidents with these systems can cause serious injury or death. Only persons

experienced with high pressure and/or combustible gas distribution systems and fluid metering

should attempt to install, adjust, or remove the flow meter. Please read all instructions carefully

before attempting to install, remove or service a flow meter.

!

ONICON will be happy to assist with technical recommendations and to provide guidance by phone
or e-mail. On-site field engineering, installation and service are also available at an additional cost.