1.4 ADDITIONAL REQUIRED HARDWARE

All ONICON insertion thermal mass meters can be installed and removed via a ¾” or larger full

port ball valve without disrupting flow. The terms “Standard” and “Hot Tap” refer to the

installation method only.

Standard Installation: Occurs during new construction or

scheduled shutdown. Once the kit is installed, the flow meter can

be installed or removed without disrupting flow.

Hot Tap Installation: For applications which require the access

hole in the pipe to be drilled through the valve using a wet tap

drilling machine while the piping system is pressurized.

NOTE: Installation hardware materials vary based on pipe

material, pipe size, the maximum operating pressure and the

maximum operating temperature.

Contact ONICON when installation hardware is required for

different pipe materials or when higher pressure or temperature ratings are required.

Part #

Kit Description

Items Included with Kit

INSTL64

Installation kit for 1” and larger welded carbon
steel pipe

Maximum operating pressure, 50 PSIG

Maximum operating temperature, 200°F

¾” full port bronze ball valve
¾” galvanized close nipple
¾” to ½” brass reducer bushing
¾” carbon steel weld-on branch outlet
½” stainless steel compression fitting with PTFE ferrules

INSTL69

Stainless steel installation kit for 1” and larger
welded carbon steel pipe

Maximum operating pressure, 50 PSIG

Maximum operating temperature, 200°F

¾” full port SS ball valve
¾” SS close nipple
¾” to ½” SS reducer bushing
¾” carbon steel weld-on branch outlet
½” stainless steel compression fitting with PTFE ferrules

INSTL70

Installation kit for 1” and larger welded carbon
steel pipe

Maximum operating pressure, 500 PSIG

Maximum operating temperature, 140°F

¾” full port bronze ball valve
¾” galvanized close nipple (Qty 2)
¾” carbon steel weld-on branch outlet
¾” stainless steel weldment with steel cable and
retaining collars
½” stainless steel compression fitting with PTFE ferrules

INSTL91

Insertion meter compression fitting w/o
installation hardware, 125psig/140° F max

½” stainless steel compression fitting with PTFE ferrules

INSTL82

Stainless steel installation kit for 1” and larger
welded stainless steel pipe

Maximum operating pressure, 500 PSIG

Maximum operating temperature, 140° F

¾” full port SS ball valve
¾” SS close nipple (Qty 2)
¾” stainless steel weld-on branch outlet
¾” stainless steel weldment with steel cable and
retaining collars
½” stainless steel compression fitting with PTFE ferrules

Compression Fitting

Reducer Bushing

Ball Valve

Close Nipple

Weld-on Branch Outlet

(INSTL 64 Shown)