Warning, Troubleshooting table – Partner B305 CBS Rev.7 User Manual

Page 14

Advertising
background image

-- 14 --

WARNING:

Always stop unit and disconnect spark plug before performing all of the

recommended remedies below except remedies that require operation of the unit.

TROUBLESHOOTING TABLE

PROBLEM

Unit won’t start or

starts but will not run.

Unit starts, but engine

has low power.

Engine hesitates.
No power under load.

Runs erratically.

Smokes excessively.

PROBABLE CAUSE

Incorrect starting procedures.
Incorrect carburetor mixture

adjustment setting.

Fouled spark plug
Fuel filter plugged.

Incorrect lever position on choke.
Dirty spark arrester screen.
Dirty air filter.

Incorrectly gapped spark plug.

Incorrect carburetor mixture

adjustment setting.

Incorrect carburetor mixture

adjustment setting.

Incorrect carburetor mixture

adjustment setting.

Incorrect fuel mixture.

CORRECTIVE ACTION

Follow instructions in the User Manual.
Have carburetor adjusted by an Authorized

Service Center.

Clean / gap or replace plug.
Replace fuel filter.

Move to RUN position.
Replace spark arrester screen.
Remove, clean and reinstall filter.
Have carburetor adjusted by an Authorized

Service Center.

Have carburetor adjusted by an Authorized

Service Center.

Have carburetor adjusted by an Authorized

Service Center.

Clean / gap or replace plug.

Use properly mixed fuel (40:1 mixture).