Remotec ZXT-120 V1.1 User Manual

Page 12

Advertising
background image

12

After included ZXT‐120 to Z‐Wave 
controller or Gateway, go to device 
setup for configuration on gateway 
or controller. 

‐ 

Input parameter number “27” and 
parameter value (please look up the 
code list of ZXT‐120 according to 
your AC brand). Then complete the 
configuration process.   

‐ 

Press the PROG button on the ZXT‐
120. (this step apply when using 
ZRC‐100 or other portable controller 
for set up, if using gateway, user can 
skip this step) 

• LED flashes once 

when ZXT‐120 
receives the 
configuration 
setting 

Go back to the control page of ZXT‐
120 on the gateway and try the 
function such as (cool, temperature 
set). 

 

If the air conditioner does not 
respond to the command you set on 
Gateway (Cool, Heat, Auto, 
Temperature set etc.), repeat step 2 
and 3 to select the next code on 
code list. 

• LED flashes once 

every time it 
receives a 
command from 
gateway  

 

L Important Information 

− Different  brand  or  model  of  air  conditioner  has  different 

function.  For  example,  some  air  conditioner  only  support 
temperature set from 18

o

C‐30

o

C, if user set 17

 o

C on gateway, 

ZXT‐120 will not respond.  

− There are more than 1 code for each brand, some does not 

support  heat,  if  user  selected  a  code  that  does  not  support 
heat  but  the  original  air  conditioner  supports  heat  function, 
please  continue  to  try  next  code  until  the  correct  one  is 
selected.  

− If none of the code works on the target air conditioner, or the 

air  conditioner  brand  is  not  shown  on  the  code  list,  please 
select code “000” for IR code learning (refer to instruction of 
IR Code Learning) 

 

 
 
 