Remotec ZXT-120 V1.1 User Manual

Page 26

Advertising
background image

26

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v1

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 1

FAN LOW (1/3)

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v2

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 1

- -

-

FAN MID (2/3)

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v2

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 5

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v1

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 3

FAN HIGH (3/3)

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v2

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 3

PARAMETER NO. =

33

SIZE = 1

SWING ON/

SWING AUTO

COMMAND_CLASS_CONFIGURATI

ON

CONFIGURATIO

N_SET

VALUE = 1

PARAMETER NO. =

33

SIZE = 1,

SWING

SWING OFF

COMMAND_CLASS_CONFIGURATI

ON

CONFIGURATIO

N_SET

VALUE = 0

PARAMETER NO. =

27

SIZE = 2,

IR CODE SETUP

COMMAND_CLASS_CONFIGURATI

ON

CONFIGURATIO

N_SET

VALUE = (CODE#)

PARAMETER NO. =

28

SIZE = 1,

NORMAL

POWER LEVEL

COMMAND_CLASS_CONFIGURATI

ON

CONFIGURATIO

N_SET

VALUE = 0

PARAMETER NO. =

28

SIZE = 1,

IR

TRANSMISSION

POWER LEVEL

HIGH POWER

LEVEL

COMMAND_CLASS_CONFIGURATI

ON

CONFIGURATIO

N_SET

VALUE = 0xFF

PARAMETER NO. =

32

SIZE = 1,

DISABLE

COMMAND_CLASS_CONFIGURATI

ON

CONFIGURATIO

N_SET

VALUE = 0

FRONT IR

TRANSMISSION

CONTROL

ENABLE

COMMAND_CLASS_CONFIGURATI

ON

CONFIGURATIO

N_SET

PARAMETER NO. =

32

Advertising