Auto Changeover 

YES 

Energy Save Heat 

NO 

Energy Save Cool 

NO 

AWAY 

NO 

ZXT‐120 functions and Parameters summaries: 

FUNCTIONS

AIR

CONDITIONER

FUNCTION

Z-WAVE COMMAND CLASS

Z-WAVE

COMMAND

COMMAND

PARAMETER

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 5

POWER ON

COMMAND_CLASS_BASIC BASIC_SET

VALUE

=

0XFF

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 0

POWER

POWER OFF

COMMAND_CLASS_BASIC BASIC_SET

VALUE

=

0X00

AUTO

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 3

COOL

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 2

FAN

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 6

HEAT

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 1

DRY

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 8

MODE

AUTO

Changeover

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 10

SETPOINT TYPE =

1,

HEAT mode

Temperature

TEMPERATURE

VALUE

SETPOINT TYPE =

2,

COOL mode

Temperature

TEMPERATURE

VALUE

SETPOINT TYPE =

8,

DRY mode

Temperature

TEMPERATURE

VALUE

SETPOINT TYPE =

10,

TEMPERATURE

SETTING

AUTO mode

Temperature

COMMAND_CLASS_THERMOSTAT

_SETPOINT

THERMOSTAT_

SETPOINT_SET

TEMPERATURE

VALUE

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v1

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 0

FAN SPEED

FAN AUTO

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v2

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 0, 2, or

4

Advertising