SDB Status Register

SDBA_STAT 0x03480000

SDBB_STAT 0x03580000

31–30 29

28 27 26 25 24

23–16

IFLAG OFLAG IFF IFE OFF OFE

IFL

R,0 R,1

R,0

R,1

R,0

R,1

R,00000000

15–8 7

6

5

4

3 2 1 0

OFL TRANS

PRI DIS

SDBCLK

CLRIF CLROF DIR

R,11111111 RW,0

RW,0

RW,0 RW,0 W,0 W,0 R,0

Field

Description (flags are active when 1)

0 Reading

DIR Transfer

direction

1 Writing

CLROF

Clear outgoing FIFO

CLRIF

Clear incoming FIFO

0 50MHz

SDBCLK SDB clock speed

1 100MHz

0

Pause transmission when FIFO is full

DIS

1 Continue

transmission even when FIFO full

0 Transmitter

wins

PRI

Priority for changing direction of transfer

1 Equal

priority

TRANS

Set to 1 after reset to make this SDB start as a transmitter

OFL

Outgoing FIFO Level: number of words that can be written

IFL

Incoming FIFO Level: number of words that can be read

OFE

Outgoing FIFO Empty

OFF

Outgoing FIFO Full

IFE

Incoming FIFO Empty

IFF

Incoming FIFO Full

OFLAG

Outgoing FIFO Flag. Set when OFLAGLEVEL writes can be performed.

IFLAG

Incoming FIFO Flag. Set when IFLAGLEVEL reads can be performed.

Advertising