Output Flag Register

SDBA_OUTPUTFLAG 0x034C0000

SDBB_OUTPUTFLAG 0x035C0000

31–24 23–16 15–8

7–0

OTRIGGER

R,00000000 RW,10000000 R,00000000

R,10000000

Input Flag Register

SDBA_INPUTFLAG 0x03440000

SDBB_INPUTFLAG 0x03540000

31–24 23–16 15–8

7–0

ITRIGGER

R,00000000 R,10000000 R,00000000

RW,10000000


Field Description

OTRIGGER Outgoing

FIFO

trigger. Set to 128 after reset.

ITRIGGER Incoming

FIFO

trigger. Set to 128 after reset.


OFLAG in the SDB status register will be 1 when there are at least OTRIGGER
spaces available in the output FIFO. OTRIGGER must be programmed with a value
between 1 and 255.
IFLAG in the SDB status register will be 1 when there are at least ITRIGGER words
in the input FIFO. This register must be programmed with a value between 1 and
255.
CLRIF and CLROF do not affect OTRIGGER or ITRIGGER.

SDB update

You should be aware that revisions of the SDB before V3.0.6 have a significantly
different processing of the status flags and a different address is used to program the
SDB flag levels for input and output. When upgrading from versions before V3.0.6,
you will need to change the code for flag programming and accessing the status bits.
You should use version V3.3.6 or above because previous versions could generate
spurious interrupts on input.