2.15 Review all of your controller configuration selections. If all the configuration selections are correct for your

application, click the SEND BOX VALUES button in the CONFIGURE section to download these settings to the

controller.

NOTE: Remember to click the SEND BOX VALUES button to update the controller any time CONFIGURE variables

have changed.


3.0 Tuning Parameter Description

3.1

In the TUNING section of the software, the various selections below are used to establish the set point and the

variables affecting set point stability.


3.2

FIXED SET TEMP. box:

a) Enter the set temperature value in degrees. This temperature must be within both the range of the selected

input sensor and the limits of low and high set ranges from the controller configuration setup. Also, verify that

the cooler is capable of safely operating at the entered set temperature. This is particularly important if you are

heating. While you can control to +100 °C using the standard thermistor, many TE devices are only rated for at

most 80 °C.

b) If you selected COMPUTER CONTROL in the CONTROL TYPE menu key under the CONFIGURE section, the values

that can be entered in the FIXED SET TEMP box range from –5.11 to +5.11. This corresponds linearly to a

fixed percentage of power output where –5.11 equals –100% power and +5.11 equals +100% power. If you

selected HEAT WP+1 and WP2- under the CONTROL MODE menu key under the CONFIGURE section, then -5.11

corresponds to full-power cooling. The value is adjustable in 0.01 unit increments.