Main Menu

The front panel interface is designed on a hierarchical menu system. The PRISM
3111/3112 allows you to choose from five submenu options As shown in
Figure 3-9.

Figure 3-9 Front Panel Main Menu Options

Alarms

The Alarms menu (Figure 3-10) allows you to view the current (last 15-minutes)
and threshold alarm status for the network and DTE lines. By pressing the Select
button on an alarm value, you can edit the threshold parameters for that alarm.
Reset capabilities allow you to zero the current alarm values.

Figure 3-10 Alarms Menu

Net

This line displays the current network signal alarm state (Table 3-1).

DTE

This line displays the current DTE signal alarm state (Table 3-2).

Alarms

Performance

Maintenance

Configuration

Utilities

Main Menu

Net

DTE

Parameters

Reset Alms

Reset Tmr

Alarms

Table 3-1 NET Alarm Indicators

Alarm

Description

Ok

No alarm threshold has been exceeded, although errors may exist which do not
exceed thresholds.

LOS

The Loss Of Signal Seconds threshold is exceeded.

OOF

The Out Of Frame Seconds threshold is exceeded.

RAI

The Remote Alarm Seconds threshold is exceeded.

AIS

The Alarm Indication Seconds threshold is exceeded.

ERR

The Errored Seconds, Severely Errored Seconds, or Bipolar Errored Seconds
threshold is exceeded.

Tst

Unit is in BERT or loop condition.

DBA

Dial Backup Active

DBF

Dial Backup Failed

Table 3-2 DTE Alarm Indicators

Alarm

Description

Ok

No alarm threshold has been exceeded, although errors may exist which do
not exceed thresholds.

T1D

T1 DTE is in LOS or OOF alarm.

P1

DTR Alarm on Port 1

P2

DTR Alarm on Port 2