Verilink PRISM 3111 (34-00242) Product Manual User Manual

Page 90

Advertising
background image

82

A

PPENDIX

A: SNMP A

GENT

SET:

dsx1NoLoop(1) - deactivates any loops active on the unit
dsx1PayloadLoop(2) - the unit will activate a PLB if no other loops are active
dsx1LineLoop(3) - the unit will activate a LLB if no other loops are active
dsx1OtherLoop(4) - the unit will activate Port Loops an any active ports, if no
other loops are active

dsx1LineStatus: (read-only)

GET:returns a sum of the following
dsx1NoAlarm(1) - the unit has no alarms
dsx1RcvFarEndLOF(2) - the unit is receiving a Yellow Alarm from the Far
End
dsx1XmtFarEndLOF(4) - unit is transmitting a Yellow Alarm
dsx1RcvAIS(8) - the unit is receiving AIS from the Far End
dsx1XmtAIS(16) - not applicable
dsx1LossOfFrame(32) - unit is currently in an OOF condition
dsx1LossOfSignal(64) - the unit is currently in a LOS condition
dsx1LoopbackState(128) - the unit has a loop active (PLB, LLB, Port 1 or
Port 2)
dsx1T16AIS(256) - not applicable
dsx1RcvFarEndLOMF(512) - not applicable
dsx1XmtFarEndLOMF(1024) - not applicable
dsx1RcvTestCode(2048) - not applicable
dsx1OtherFailure(4096) - not applicable

dsx1SignalMode: (read-write)

GET:

none(1) - this signal mode is the only mode supported
robbedBit(2) - not applicable
bitOriented(3) - not applicable
messageOriented(4) - not applicable

SET:

none(1) - not applicable
robbedBit(2) - not applicable
bitOriented(3) - not applicable
messageOriented(4) - not applicable

dsx1TransmitClockSource: (read-write)

GET:

loopTiming(1) - Network Timing is set to Network Clock
localTiming(2) - the Network Timing is set to Internal Clock
throughTiming(3) - the Network Timing is set to Port 1 Clock or Port 2 Clock