Alarms, Net alarms – Verilink PRISM 3111 (34-00242) Product Manual User Manual

Page 56

Advertising
background image

48

C

HAPTER

4: T

ERMINAL

I

NTERFACE

Alarms

The Alarms screen (Figure 4-3) allows you to view the current alarm status of the
network and the DTE interfaces.

Figure 4-3 Alarms Screen

Net Alarms

These status lines display the selected element’s current network signal alarm state
(Table 4-2). Alarms are determined by the selectable thresholds in the Alarm
Configuration screen on page 61.

Table 4-2 NET Alarm Indicators

Alarm

Description

OK

No alarm threshold has been exceeded, although errors may exist which do not
exceed thresholds.

ERR

The Errored Seconds, Severely Errored Seconds, or Bipolar Errored Seconds
threshold is exceeded.

LOS

The Loss Of Signal Seconds threshold is exceeded.

OOF

The Out Of Frame Seconds threshold is exceeded.

RAI

The Remote Alarm Seconds threshold is exceeded.

AIS

The Alarm Indication Seconds threshold is exceeded.

UAS

The Unavailable Seconds threshold is exceeded.

TST

Unit is in BERT or loop condition.

DBA

Dial Backup Active

DBF

Dial Backup Failed