Dial - Sends reports through a modem to the SLIP server.

The unit attempts three times to connect using the primary number. If all three
attempts fail, it will attempt three times to connect using the secondary number (if
it is not blank). If the secondary number fails, the unit waits five minutes and then
attempts to communicate with the primary number again. When a connection is
detected, the unit outputs the trap message and then disconnects.

Dirct - (Direct) Sends reports directly to the SLIP server.

Prim Dial String.

This field is an ASCII string for the primary call on alarm phone

number used in the Dial mode. The string must NOT include the ATDT command
prefix.

Sec Dial Str.

This field is an ASCII string for the secondary call on alarm phone

number used in the Dial mode. The string must NOT include the ATDT command
prefix.

Init Dial Str.

The modem initialization string is entered in this field. Refer to the

modem’s documentation for further information. The default setting is

ATEQ0V1

.

Dis Conn Str.

This field identifies the character string to be output when the

modem session is terminated. The default setting is

ATH

.

Comp SLIP.

The Auto setting allows the unit to negotiate with the far end to

enable or disable SLIP compression, depending on the type of connection.
Selections are Auto, Dis and En.

Utilities

The Utilities screen (Figure 3-18) allows you to perform various functions such as
setting the time and date, configuring optional ports and their rates, and saving
configuration settings.

Figure 3-18 Utilities Menu

SUPV

Selections are 1.2, 2.4, 9.6 and 19.2 K.

SLIP

Selections are 1.2, 2.4, 9.6 and 19.2 K.

SUPV

SLIP

Date

Time

Set Password

Utilities

Maint Rst

Fact Rst

Contrast

Download