Span endpoints screen, Span endpoints screen -13 – Verilink WANsuite 6450 (34-00326) Product Manual User Manual

Page 121

Advertising
background image

V T 1 0 0 I n t e r f a c e

4-13

LOSWS

Sets the threshold for the number of Loss of Sync Word Seconds within any
given 15-minute performance data collection interval. If the value of LOSW
in a particular 15-minute collection interval reaches/exceeds this value, a trap
is generated. One trap will be sent per interval per endpoint. A value of 0
(zero) disables the trap.

UAS

Sets the threshold for the number of Unavailable Seconds within any given
15-minute performance data collection interval. If the value of UAS in a
particular 15-minute collection interval reaches/exceeds this value, a trap is
generated. One trap will be sent per interval per endpoint. A value of 0 (zero)
disables the trap.

Span Endpoints Screen

Selecting the “Span Endpoints” prompt on the WANsuite 6450 Network
screen will display the screen shown in Figure 4.12.

Figure 4.12

Span Endpoints Screen

This screen displays each endpoint of the span. If the SHDSL link is not up,
only the local side of the span is displayed. The EOC channel is used to
access the remote end unit

The Span Endpoints Details screen (Figure 4.13, accessed by selecting from
the <Unit> column) supports retrieval of unit inventory information available
via the EOC from units on an SHDSL line, and provides details regarding the
parameters listed below.

Advertising