CHAPTER 1 • INSTALLING THE SMARTSENSOR 105

13

33 / 10.1

23 / 7

19 / 5.8

33 / 10.1

34 / 10.4

23 / 7

19 / 5.8

34 / 10.4

35 / 10.7

23 / 7

20 / 6.1

35 / 10.7

36 / 11

23 / 7

20 / 6.1

36 / 11

37 / 11.3

23 / 7

20 / 6.1

37 / 11.3

38 / 11.6

24 / 7.3

21 / 6.4

38 / 11.6

39 / 11.9

24 / 7.3

21 / 6.4

39 / 11.9

40 / 12.2

25 / 7.6

22 / 6.7

40 / 12.2

41 / 12.5

25 / 7.6

22 / 6.7

41 / 12.5

42 / 12.8

26 / 7.9

22 / 6.7

42 / 12.8

43 / 13.1

26 / 7.9

22 / 6.7

43 / 13.1

44 / 13.4

27 / 8.2

23 / 7

44 / 13.4

45 / 13.7

27 / 8.2

23 / 7

45 / 13.7

46 / 14

28 / 8.5

23 / 7

46 / 14

47 / 14.3

28 / 8.5

24 / 7.3

47 / 14.3

48 / 14.6

29 / 8.8

24 / 7.3

48 / 14.6

49 / 14.9

29 / 8.8

24 / 7.3

49 / 14.9

50–180 / 15.2–54.9

30 / 9.1

25 / 7.6

Must be < offset

Table 1.1 – Mounting Height Guidelines

Attaching the Mount Bracket to the Pole

Before attaching the mount bracket to the pole, first make sure that your cables are long

enough to reach the sensor height and to stretch across the distance from the sensor to the

cabinet.

Follow the steps below to correctly attach the mount to the pole (see Figure 1.2):
1 Look up the recommended mounting height from Table 1.1.

2 Insert the stainless steel straps through the slots in the mount bracket.

3 Position the mount on the pole so that the head of the mount is pointing towards the

middle of the lanes of interest.

4 Tighten the strap screws.