Configuration by Web Tool

The EDW-100 includes an easy-to-use Web
configuration tool. The Web tool is very intuitive
and includes useful help information for the
configurable parameters.
Connect and login to the EDW-100 with the
EDW-100 Config account on the default IP
address and with default username- and password
combination (or your customized if configured)
using a standard Web browser.
Use the Configuration Wizard to set all
parameters then press the button "Program Unit"
to write the parameters into the unit or save the
parameters to a file.

Serial/IP® and Telnet Options
EDW-100 are bundled with Serial/IP® virtual Com port director software. The Serial/
IP® use portions of the “Telnet Environment Option” (RFC1572) to verify that it is
connected to an EDW-100.
The EDW-100 has partial support for the “Telnet Com Port Control Option” (RFC2217).
This makes it possible to remotely (on the fly) change serial port parameters. Currently
supported parameters are baud rate, parity, number of data bits and number of stop bits.
As default the Telnet Options are disabled. If the Serial/IP® software is to be used, the
Telnet options must be enabled in the web tool. This parameter can be found on the
Serial/IP page.