Westermo EDW-100 User Manual

Page 24

Advertising
background image

24

6616-2203

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary to the rails and connected to this port.

The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This earthing

point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar,

where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation

and may be directly connected to the protective earth.

RS-232
Electrical specification

EIA RS-232

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.

Protocol

Transparent, optimised by packing algorithm

Retiming

Not applicable

Circuit type

SELV

Transmission range

15 m

Isolation to

Power 2 kV
Ethernet 1; 1.5 kV

rms

Connection

9-pin D-sub male (DTE)

Shielded cable

Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close to
rails*

Conductive housing

Isolated to all other circuits

Number of ports

1

Ethernet
Electrical specification

IEEE std 802.3. 2000 Edition

Data rate

10 Mbit/s or 100 Mbit/s, auto-negotiated or manually set by
DIP-switches

Protocol

UDP, TCP, ICMP, HTTP and ARP

Duplex

Full- or half duplex, auto-negotiated or manually set by DIP-
switches

Circuit type

TNV-1

Transmission range

100 m

Isolation to

Power 2 kV

rms

RS-232 1.5 kV

rms

RS-422/485 1.5 kV

rms

Connection

RJ-45 shielded, auto MDI/MDI-X

Shielded cable

Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails*

Conductive housing

Isolated to all other circuits