Parameter of the integrated PAD

Using the PAD command “set x:n” you can change the parameter according to ITU
specification X.3.
After changing one or more X.3 parameter you can store the change non volatile by issu-
ing “exec save”. The stored parameter can be reloaded with the command “exec load”.
After an X.25 connection is cleared the PAD parameter will be reset to the last active pro-
file (rsp. default).

International Parameters 1 through 12

1

Enable (disable) switch to command mode

Defines whether the terminal user may switch from data to command
mode (e.g. to change a X.3 parameter), and – if he may – which key(s)
must be pressed to make the switch.

Valid Parameter Values:
0

Switch to command mode disabled.

1

Switch to command mode enabled
switch by pressing the key combination <CTRL>+P
(hexdecimal 10, decimal 16)

n

Switch to command mode enabled
switch by entering the ASCII character, that corresponds to the parameter
value n (decimal integer value in the range between 32 and 126).

2

Echo

Determines whether a character will be echoed to the terminal data
transfer mode.

Valid Parameter Values:
0

No echo

1

Echo