v110llc – Usage of LLC for V.110 connections

If set the LLC parameter will be used for incoming and outgoing V.110 connections.

0: LLC is ignored and not created (default).
1: Ougoing call: An LLC is sent deriving from the settings of the TA

incoming call: The received LLC is used to setup the parameters for the
V.110 connection.

v110flc – Usage of V.110 flowcontrol

0: V.110 flowcontrol via xbits will be ignored.
1: V.110 flowcontrol via xbits enabled (default).

w – X.25 L3 windows size

L3 window size parameter. This parameter is only valid when X.25 protocol is used.
(default: 2)

xnr – Own X.25 address

Setup an origination X.25 address.
Only necessary, if not supported from the network (X.31B channel only)

xtab – Show table xtab

Show setting of all entries of the table xtab for translation of X.25 address to set ISDN
number.

X25mb – Handling more data bit (M-Bit)

All characters out of X.25 packets that are continued using the “more data bit” (M-Bit)
will output to the V.24 interface as a contiguous data stream (without any pauses). All
from the ISDN line received X.25 packets with more data bit set will be collected inside
the ID-90. Ouput to the V.24 interface will be started if an X.25 packet without “more
data bit” set is received or a data length of 2 048 octetts is assembled.

0: received X.25 data will be output independent of setting of M-Bit (default)
1: received X.25 data will be collected til M-Bit off.