Westermo ID-90 User Manual

Page 66

Advertising
background image

66

6607-2204

Configuration using the TA+Configurator commands (remote)

The ID-90 to be configured is referred here as “remote ID-90”.
The ID-90 to configure is referred as “local ID-90”.
Please make sure that the remote ID-90 to be configured at the other end is connected to
the ISDN line and powered up.

• Connect the local ID-90 to ISDN interface
• Connect the PC's com-port to the DTE interface of the local ID-90.
• Connect the power supply to the mains socket.
• Start a terminal emulation program (i.e. Windows-Terminal)
• Configure the local ID-90 with the B channel protocol X.75

and blocksize 2048 (ATB10).

• Set up an ISDN connection to the remote ID-90 to be configured by using the com-

mand: ATD<ISDN-No>e<

>. The extension “e” at the end of the calling number gives

a connection to the internal remote access of the remote TA+PP2.
The called ID-90 configurator acknowledges by requesting the remote password. Please
enter the correct password (default: no password, just return). Now you can work with
the configurator by using the TA+Configurator commands.

• Configure the parameter for the remote ID-90 from your terminal program and store

them (if wanted).

Example: To change the used B channel protocol to X.75 please enter the following com-

mands:
prot 10<

> (set protocol to X.75 – blocksize 2048)

save<

>

(save the new configuration)

Hint:

The active set of parameters can be displayed on screen by the configurator
with the command “show<

>”.

If necessary the remote ID-90 can be reset using the command “reset<

>”.

• Hang up the ISDN connection by leaving the configurator using the command quit.

Leave your terminal program. After the next reset the changes will be active.

Now the configured remote ID-90 with the new set of parameters can be used by running
the needed PC program.