Flc – flowcontrol, Hlc – higher layer compability, Help – Westermo ID-90 User Manual

Page 76: Idle – idle data timeout, K – windowsize, Lcgr – logical group number x.25, Llc – low layer compatibility, Load – load stored parameter setting, Loadsw – load dip-switches parameter setting

Advertising
background image

76

6607-2204

flc – Flowcontrol

Flowcontrol to DTE

0: No flowcontrol
3: Hardware flowcontrol RTS/CTS (default)
4: Software flowcontrol XON/XOFF

hlc – Higher layer compability

Higher layer compatibility for outgoing call.

(see note 2 page 85)

help

Displays help texts for all commands

idle – Idle data timeout

Timer to disconnect the ISDN B channel connection after inactivity.

0: inactive (default)
1..n: delay time to disconnect in seconds (1..255).

isdn – ISDN D channel protocol (note 1, page 85)

Selects ISDN D channel protocol

0: DSS1 (Euro-ISDN)
8: VN4 (French)

k – Windowsize

Layer-2 protocol: windowsize (default:7). k = {1..7}
Value will be automatically changed with changing B channel protocol prot.

lcgr – Logical group number X.25

Logical group number for X.25 packet layer protocol.

lcgr = {0..255}, default: 0

llc – Low layer compatibility

Low layer compatibility for outgoing calls (Hex bytes)

(see note 2 and 3, page 85)

load – Load stored parameter setting

All parameters stored in non volatile ram will be loaded.

loadsw – load DIP-switches parameter setting

Parameters entered via the DIP-switches will be loaded and active the same way as if a
power on was exexuted.

Advertising