4 power supply – Westermo RM-505U-K User Manual

Page 25

Advertising
background image

man_505U-K_1.4.doc

Dec 2008

ELPRO Technologies Pty Ltd 2008

Page 25

3.4 Power Supply

3.4.1 Battery Pack BU-5-2

The BU-5-2 can be installed underneath the 505K or beside it. The BU-
5-2 uses the same type of enclosure as the 505K and is mounted in the
same way. The BU-5-2 has a “cable tail” which plugs into the 505K.
The input wiring is then connected to a socket on the BU-5-2.

The lid of the BU-5-2 can be rotated to suit installation.

A second BU-5-2 can be connected to the first in a similar manner. The
input wiring for the 505K is then connected to the socket on the second
BU-5-2.

All plugs and connectors should be waterproofed with waterproofing
tape.

Check the label on the back of the BU-5-2 to make sure that it has been factory-set to 9V.

The BU-5-2 takes six alkaline AA batteries - such as Duracel MX1500 or Eveready E91. Do
not use rechargeable batteries in the BU-5-2 as their self discharge life is short. The
temperature rating of the BU-5-2 depends on the battery type - for alkaline batteries, this is
typically -10 to 50 degC. Special “industrial” batteries, such as Eveready EN91, have a wider
temperature range, -30 to 55 degC.

Operation of the 505K will stop during battery change, however configuration of the module

ELPRO

505U-K

WIRELESS

MONITORIN

G

OK
TX

INPUT
WIRING

ELPRO

BU-5

BATTERY

PACK

ELPRO

505U-K

WIRELESS

MONITORING

OK
TX

ELPRO

BU-5

BATTERY

PACK

INPUT
WIRING

ELPRO

BU-5

BATTERY

PACK

INSTALLING
SECOND BU-5-2
BATTERY PACK

Advertising