Large Dehumidifying Dryers

Controls

51

The trend colors match the colored line underneath the values description in the main
part of the display.

The maximum and minimum values for the trend can be changed by pressing the
trend itself and entering new values for the appropriate pens.

2. Press “Regen Trend” to active a trend window.

The trend window displays 4 hours worth of values for the regeneration temperatures.
The trend only collects data while the trend display is active

The trend colors match the colored line underneath the values description in the main
part of the display.

The maximum and minimum values for the trend can be changed by pressing the
trend itself and entering new values for the appropriate pens.

3. Press “Dew Point Switch” to change the value at which the regeneration system

switches sides and begins a new regeneration cycle if the option, switch on dew
point, is enabled.

4. Press “Dryer Menu” to return to the dryer menu display.

5. Press “Help” to access the help menu display.

The 2 message bars at the bottom indicate what the regeneration cycle is doing. The upper
line is used for the right bed while the lower line is used for the left bed. If a time appears as
part of the message, its format is HOURS:MINUTES.

The right bed messages are:

RIGHT BED UNDEFINED

– Main Air Valve position is undetermined

RIGHT BED OFF-LINE

– Bed is not in process and requires regeneration

RIGHT BED OFF-LINE & READY

– Bed is not in process and has completed regeneration

RIGHT BED REGEN-HEAT H:M

– Regeneration in progress, heating active

RIGHT BED COOLING H:M

– Regeneration in progress ambient air cooling active

RIGHT BED CLOSED LOOP H:M

– Regeneration in progress closed loop cooling active

RIGHT BED IN PROCESS H:M

– Bed is being used to dry the process air

RIGHT BED REGEN FAILURE

– Regeneration failed

DRYER SHUT OFF

– Dryer is not functioning

DRYER IS STOPPING IN H:M

– Sequenced shutdown in progress

The left bed messages are:

LEFT BED UNDEFINED

– Main Air Valve position is undetermined

LEFT BED OFF-LINE

– Bed is not in process and requires regeneration

LEFT BED OFF-LINE & READY

– Bed is not in process and has completed regeneration