4-7 Program Upgrade Procedures

The AP1+ PLC and touch screen both use compact flash memory cards for data and program
storage. Occasionally, a program upgrade will become available from ACS for the AP1+
PLC, touch screen or both. The customer will receive the upgrade(s) by way of a new
compact flash card. Follow the instructions in this document to upgrade the specific
component.

PLC Program Upgrade

• Option – Save the dryers settings before executing this procedure.

• Power down the dryer and access the dry air source control enclosure.

• Remove and retain the existing memory card from the PLC.

• Turn on DIP switch 1-2 (Located under the CPU cover).

• Insert the upgrade memory card.

• Power up the dryer.

o When the PLC “Busy” LED stops flashing the PLC upgrade is complete.

• Power down the dryer.

• Remove the upgrade memory card.

• Re-insert the original memory card.

• Power up the dryer, inspect and verify the new version number(s)

• Start the dryer as required.