Danger – AEC AP Series Large Dehumidifying Dryer User Manual

Page 89

Advertising
background image

Large Dehumidifying Dryers

Maintenance

88

6. Inspect the gaskets on each of the covers. Replace if necessary.
7. Re-install the covers.

Figure 14: Desiccant Tower Assembly

Regeneration

Heater Cover.

High

Temperature

Gaskets.

Heater Element
Mounting Plate.

Access cover can be

removed in order to

replace desiccant.

Viewing Glass, for

checking the status of

the desiccant inside.

Regeneration

Heaters

High

Temperature

Gaskets.

Stainless Steel

Hollow Core

Desiccant Tank

Desiccant Tank

Mounting

Platform

Figure 15: Desiccant Replacement Amounts

Replacing the Process Heater (Electric Dryers)

Large Dryers have a number of single phase Calrod-type heater elements wired in a delta
formation. They are mounted on top of the dryer or to the drying hopper. The number and
wattage of the heaters varies with model, voltage, temperature range, etc., but the
replacement procedure is the same.

DANGER!

Disconnect and lock out power before heater replacement.

Dryer

Desiccant Required per Tower

CFM

“13 X”, 8 x 12 Bead

Total

600 175 350
850 175 350
1000 300 600
1250 300 600
1500 300 600
2000 300 1200
2500 300 1200
3000 300 1200

Advertising