2 electrical faults – AEC Colortronic MSH Series 2039 User Manual

Page 38

Advertising
background image

C Series Granulators

Troubleshooting

38 of 53

6-2 Electrical Faults

Problem

Possible Cause

Possible Remedy

Supply failure

Check fuses

Starter inoperative

Check main supply

Starter overloads or cuts out

Check motor requirements
and adjust accordingly

Motor Fails to Start

Safety switches inoperative

Check and adjust as needed

Too much belt tension

Check belt tension and adjust
as necessary

Incorrectly connected motor

Check terminal connection
with manufacturer’s
connection diagram and
adjust as necessary

Motor starts but will not take
load

Defective starter winding

Check current in each phase
with ammeter, if there is a
marked difference in current
in one phase, contact motor
manufacturer

Motor will start when
disconnected from load but
not when connected

Worn bearings

Check and replace if
necessary according to
manufacturer’s literature

Advertising
This manual is related to the following products: