Troubleshooting

22

3A1183D

Digital Display Messages

No display does not mean that spayer is not
pressurized. Relieve pressure before repair. See
Pressure Relief Procedure
, page 13

DISPLAY

SPRAYER OPERATION

INDICATION

ACTION

No Display

Sprayer stops. Power is
not applied. Sprayer may
be pressurized.

Loss of power.

Check power source. Relieve
pressure before repair or disas-
sembly.

Sprayer is pressurized.
Power is applied. (Pres-
sure varies with tip size
and pressure control set-
ting.)

Normal operation

Spray

Sprayer may continue to
run. Power is applied.

Pressure greater than 4500 psi
(310 bar, 31 MPa) or pressure
transducer faulty

Replace pressure control board or
pressure transducer

Sprayer stops. Power is
applied.

Pressure transducer faulty, bad
connection or broken wire.

Check transducer connection.
Open prime/pressure relief valve.
Substitute new transducer for
transducer in sprayer. If sprayer
runs, replace transducer.

Sprayer stops. Power is
applied.

Line voltage too high.

Check for voltage supply problem

Sprayer does not start or
stops. Power is applied.

Motor fault

Check for locked rotor, shorted
wiring or disconnected motor.
Repair or replace failed parts.

Sprayer stops. Power is
applied.

Motor is too hot.

Allow sprayer to cool. If sprayer
runs correctly when cool, check
motor fan function and air flow.
Keep sprayer in cool location. If
sprayer does not run when cool
and continues to blink 6 times,
replace motor.

Power is applied.

Pressure less than 200 psi (14
bar, 1.4 MPa)

Increase pressure if desired.
Prime/pressure relief valve may
be open.

Sprayer stops or does not
run.

High input voltage

Check power source for correct
voltage.

Advertising