Operation, Setup, Prime and flush storage fluid – AIRLESSCO TS1500 User Manual

Page 7: Flushing

Advertising
background image

Operation

3A1183D

7

Operation

Setup

Connect the hose and gun

1. Remove the plastic cap plug from the outlet and

screw a conductive or grounded 3000 psi spray
hose onto fluid outlet.

2. Connect an airless spray gun to the other end of the

hose. Do not install spray tip.

NOTE: Do not use thread sealer on swivel unions as
they are made to self seal.

Fill the Packing Nut/Wet Cup

1. Fill the Packing Nut with 5 drops of ASM Packing

Seal Fluid.

Flush the Sprayer

1. Flush the sprayer. See Flushing Procedure on

page

7.

Prime and Flush Storage Fluid

Before beginning a new spraying project you need to
prime the sprayer and flush the storage fluid out of the
sprayer.

Oil- or Water-based Materials

When changing from water-based material to oil
based material, flush with soapy water and then
mineral spirits.

When changing from oil based material to water
base material, flush with mineral spirits, followed by
soapy water, then a clean water flush.

When flushing with solvents, ground pail and gun.

Flush before changing colors, before fluid can dry in
the equipment, at the end of the day, before storing,
and before repairing equipment.

Flushing

1. Make sure the gun trigger lock in engaged and there

is no spray tip in the gun. Refer to the separate

• To reduce the risk of static sparking, fire or

explosion which can result in serious bodily injury
and property damage, always ground the sprayer
and system components and the object being
sprayed, as instructed in the safety warning section
of this manual.

• Ensure electrical service is 120 VAC, 20 amp

minimum and the outlet is properly grounded.

• For generator power, a minimum 7000 watt

generator with a voltage regulation must be used.

ti15987a

NOTICE

The equipment was tested with lightweight oil,
which is left in the fluid passages to protect parts.
To avoid contaminating your fluid with oil, flush the
equipment with a compatible solvent before using
the equipment for the first time.

• To reduce the risk of static sparking, which can

cause fire or explosion, always hold a metal part of
the gun firmly against the metal pail when flushing.
This also reduces splashing.

• Always remove the spray tip before flushing.

Advertising