15 motion setup – Eneo EDC-3371 User Manual

Page 30

Advertising
background image

30

• RELAY OUT

This function can operate only when the relay output setup has the time in the alarm menu.

Example:

RELAY OUT SETUP

OUT:

ALARM

OUT:

 MIN

OUT3:

ALARM

OUT4:

5 MIN

EXIT (ESC TO EXIT)

You can select OUT or OUT4 and press

CTRL or IRIS OPEN then that relay operates during the setting time only.

4.15 Motion Setup

The motion detection function is available in the preset mode only. After you set the motion in any preset, when you call the preset with the motion, the motion
detection operates.
In the preset setup, you can set the motion setup as below.

To enable the motion on the preset, set MOTION to

ON.

To enter the MOTION SETUP, push the

joystick to right on the MOTION SETUP.

PRESET SETUP

NUMBER

: 00

TITLE

: – – –

CAMERA SET

DWELL

: – – – SEC

  3 4 5 6 7 8 9 0   3 4 5 6 7 8 9 0
00 * * – – – – – – – – – – – – – – – – –
0 – – – – – – – – – – – – – – – – – – – –
04 – – – – – – – – – – – – – – – – – – – –
06 – – – – – – – – – – – – – – – – – – – –
NEXT PAGE
SAVE AND EXIT (ESC TO CANCEL)

PRESET CAMERA SETUP

FOCUS

: AUTO

MOTION

: OFF

MOTION SETUP
AE SETUP
SAVE AND EXIT (ESC TO EXIT)

MOTION SETUP

SENSITIVITY

: 07

POSITION

: ALL

DELAY

: 00SEC

OUTPUT

: OFF

HOLD TIME

: 03SEC

EXIT (ESC TO EXIT)

SENSITIVITY

-0

POSITION

ALL, CENTER (the center box displays): motion detection area.

DELAY

00-05SEC:

The delay time is used to make adjustments for scenes that have sudden changes such as lights and shadows

created by headlights of nearby traffic. The motion action occurs only when the motion keeps continuously during

the delay time.

OUTPUT

OFF, OUT, OUT, OUT3, OUT4: relay output

HOLD TIME

03-99SEC:

The hold time starts to count after the motion detects.

When a motion occurs, the dome activates the relay output, displays the message of „MOTION” on the screen, and sends the command of „ALARM 8” to the
keyboard.

Advertising