H3C Technologies H3C S12500 Series Switches User Manual

Page 31

Advertising
background image

24

# Display ENDC information.

[SwitchA] display evi neighbor-discovery client summary

Status: I-Init E-Establish P-Probe

Interface Local Address Server Address Network ID Auth Status

Tunnel0 1.1.1.1 1.1.1.1 1 disabled E

# Display EVI neighbors registered with the ENDS.

[SwitchA] display evi neighbor-discovery server member

Interface: Tunnel0 Network ID: 1

IP Address: 1.1.1.1

Client Address System ID Expire Created Time

1.1.1.1 000F-0001-0001 25 2012/01/01 00:00:43

1.1.2.1 000F-0001-0002 15 2012/01/01 01:00:46

1.1.3.1 000F-0001-0003 20 2012/01/01 01:02:13

# Display neighbor entries that Switch A has learned.

[SwitchA] display evi neighbor-discovery client member

Interface: Tunnel0 Network ID: 1

Local Address: 1.1.1.1

Server Address: 1.1.1.1

Neighbor System ID Created Time Expire Status

1.1.2.1 000F-0001-0002 2012/01/01 12:12:12 13 Up

1.1.3.1 000F-0001-0003 2012/01/01 12:12:12 12 Up

2.

Verify the configuration on Switch B:
# Display information about the EVI tunnel interface.

[SwitchB] display interface tunnel 0

Tunnel0

Current state: UP

Line protocol state: UP

Description: Tunnel0 Interface

Maximum Transmit Unit: 64000

Internet protocol processing: disabled

Tunnel source 1.1.2.1

Tunnel keepalive enabled, Period(20 s), Retries(2)

Network ID 1

Tunnel protocol/transport GRE_EVI/IP

Last clearing of counters: Never

Last 300 seconds input rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec

Last 300 seconds output rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec

Input: 0 packets, 0 bytes, 0 drops

Output: 0 packets, 0 bytes, 0 drops

# Display information about EVI-Link interfaces.

[SwitchB] display evi link interface tunnel 0

Interface Status Source Destination

Evi-Link1 UP 1.1.2.1 1.1.1.1

Evi-Link2 UP 1.1.2.1 1.1.3.1

# Display ENDC information.

[SwitchB] display evi neighbor-discovery client summary

Status: I-Init E-Establish P-Probe

Advertising