Timing web page – Grass Valley 8960DEC User Manual

Page 34

Advertising
background image

34

8960DEC—Instruction Manual

Configuration

Timing Web Page

The Timing web page shown in

Figure 15

appears when he optional

8900FSS Frame Sync submodule is installed on the 8960DEC module. If the
submodule is not installed, the web page will appear as shown in

Figure 16

on page 35

.

The Timing web page provides lock source selection and fine phase adjust-
ments along with freeze controls for the input video. Refer to the Configu-
ration Summary in

Table 4 on page 21

for a summary of what video lines

are affected by each control, all parameters, step sizes, and default values.

Use the Timing display to set the following parameters:

Choose a Lock Source from

Reference

input or

Video In

input.

Adjust

H Phase

in nanoseconds and

V Phase

adjustment in lines.

Set

Freeze Recognition

to

Manual

or

Auto

.

Selecting

Auto

stores the last field

in the Frame Synchronizer to use if the input video is lost or corrupted.

Set the

Freeze Mode

to

Frame

or

Field

.

Set the

Freeze Field

to

Field 1

or

Field 2

.

Set the

Freeze Signal

to

Last Field

or

Black

. This will determine the freeze

signal when a freeze is activated in either

Auto

or

Manual

mode.

To perform a manual freeze, click the

Freeze

button at lower left.

Use
this
link