Service – Grass Valley 8960DEC User Manual

Page 44

Advertising
background image

44

8960DEC—Instruction Manual

Service

Service

The 8960DEC modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.

If your module is not operating correctly, proceed as follows:

Check frame and module power and signal present LEDs.

Verify power at the voltage testpoints (see

Figure 21

) and check Fuse F1

if no voltage is detected.

Check for presence and quality of input signals.

Verify that source equipment is operating correctly.

Check cable connections.

Check output connections for correct I/O mapping (correct input con-
nector is used for the corresponding channel output).

Refer to

Figure 6

for the location of PWR LED and

Table 2 on page 17

for

proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the 8960DEC at the front of this document for the Grass Valley Cus-
tomer Service Information number.

Figure 21. Fuse and Voltage Testpoint Locations

JP13

pin 1, +5 V

pin 3, -5 V

JP1

JP13

Voltage Testpoints

Fuse: 2 A FAST

125 V

F1

Ground Testpoint

Advertising