4 detailed operating procedure, 1 network configuration, 1 utp negotiation – Grass Valley FXE-1501 User Manual

Page 13: 2 utp speed, 3 utp duplex, Detailed operating procedure, Network configuration, Utp negotiation, Utp speed, Utp duplex

Advertising
background image

GUIDE TO INSTALLATION AND OPERATION

FXE-1501 | 9

4 Detailed Operating Procedure

The basic operating characteristics of the FXE1501 can be adjusted using the Config/Status panel in the iControl GUI,
or the on-board menu using the local control panel.

• Refer to the menu on page 17 for help in accessing the indicated items using the local control panel.
• The relevant section of the iControl GUI is shown here; select the desired option by clicking the appropriate

radio button:

• In all lists of optional values for a parameter, the underlined value is the default value.
• Terminology: UTP = Unshielded Twisted Pair (descriptive of the Ethernet network wiring)

4.1 Network Configuration

4.1.1 UTP Negotiation

When AUTO is selected, The FXE-1501 will communicate with the Ethernet at the highest available rate, and the UTP
Speed and UTP Duplex selections will be disabled (gray).

When MANUAL is selected, the FXE-1501 will communicate with the Ethernet at the rate selected in the UTP Speed
menu (see the next section).

• Available choices: [AUTO, MANUAL]

4.1.2 UTP Speed


Set the Ethernet connection speed to the selected value when MANUAL is selected as the UTP Negotiation option.

• Available choices: [1000, 100, 10]


Note that on the fiber-optic interface, the speed is fixed to 1000.

4.1.3 UTP Duplex


Choose whether to operate the Ethernet connection as a full-duplex or a half-duplex link when MANUAL is selected
as the UTP Negotiation option.

• Available choices: [FULL, HALF]


Note that FULL is forced when the Ethernet connection speed is 1000