Configure Network Configuration page - Redundant K2 SAN server A and server B

This page displays the control network Ethernet port, and allows you to configure the FTP/Streaming
network Ethernet port.

NOTE: This page does not configure the iSCSI interface (media network) ports.

1. Verify that the top port is configured correctly.

The top port is the port over which the K2Config application is communicating. If correctly
configured, it is already assigned the control network IP address, as displayed on this page.

2. If the server has the role of FTP server, verify that the other port is configured correctly. If not

configured correctly, do the following:

a) Select the other port and click

Modify

.

A network configuration dialog box opens.

b) Enter the FTP/Streaming IP address and the subnet mask and click

Apply

.

For systems with an optional NH (FTP) server, the server you are now configuring does not take
the role of FTP server, so configuring the second port here for the FTP/streaming network is not
required.

3. Click

Next

.

The File System Server Configuration page opens.

Configure File System Server Configuration page - Redundant K2 SAN server A

1. Enter the name or IP address of the redundant K2 Media Server (server B).

Do not yet enter anything in the File System Server #2 box.