Connect serial engine to network, Connect serial, Engine to network – Grass Valley Machine Control Interfaces V.12.0 User Manual

Page 68

Advertising
background image

68

Kalypso Machine Control Interfaces Installation Instructions

Section 3 — VTR Interface

You can change this if you wish, using the rules below.

If you have a UK keyboard, you should be able to enter the text
directly.

If you have a US keyboard, you need to type the @ character to enter
the “ character. (On US keyboards these characters are swapped,
and the Delete key behaves the same as the backspace key.)

Typing does not replace highlighted text. Use the backspace key to
delete existing text.

9.

Scroll to

Set Inet$EtherIPAdd

and enter an IP address. The default line

should read:

set Inet$EtherIPAddr "192.168.0.15"

You can change this to a value compatible with your system using the
“ or @ key as necessary for your keyboard.

10.

Scroll to

Set Inet$EtherIPMask

and enter a subnet mask. The default line

should read:

Set Inet$EtherIPMask "255.255.255.0"

You can change this to a value compatible with your system using the
“ or @ key as necessary for your keyboard.

11.

Press

F3

to open a Save As dialog box, then click

OK

to save the

configuration. Then close only the two configuration windows by
clicking on the x boxes in the top left corner of each. Leave the

HardDisk4

window open.

12.

Check that the configuration is correct by pressing

Ctrl

Break

to reboot

the Serial Engine. Error messages will appear because the Serial Engine
is not connected to a network with the Encore sharer application
running. This the expected behavior and these messages can be safely
ignored. Press

Esc

to return to the Acorn desktop. Confirm that the new

name and/or new IP address

appear on the front control panel.

13.

Power off the Serial Engine.

14.

Disconnect the monitor, keyboard, and mouse.

15.

Reattach the front panel.

Connect Serial Engine to Network

1.

Power off the Serial Engine.

2.

Connect the Ethernet cable to the rear of the Serial Engine.

3.

Power up the Serial Engine.

Advertising