Updating Licensed Internal Code

RAID Instructions

3-11

3. Enter a new rebuild time. The new rebuild time is effective for the next rebuild

operation.

The Change Logical Unit Parameters screen appears.

NOTE: Tektronix recommends a minimum rebuild time of 8 hours when using
multiple video channels.

Updating Licensed Internal Code

The Licensed Internal Code (LIC) diskette may also include an update to the SP
programmable read-only memory (PROM) code. When you install Licensed Internal
Code, the SP tries to copy it to reserved areas outside operating system control on four
disk modules, which are called the database disks. The database disk modules are A0,
B0, C0, and A3. (See the figure below.)

For the LIC installation to succeed, at least two of the database disk modules must be
on-line, and ideally, all of them should be on-line. A disk module is on-line if it is
fully powered up and not faulted; that is, if it has a status code on the Presentation
Utility screen and this code is not

POW

or

OFF

. Having multiple copies of code offers

higher availability if a disk module fails.

Disk modules the SP uses to store Licensed Internal Code

A0 B0 C0 D0 E0

A1 B1 C1 D1 E1

A2 B2 C2 D2 E2

A3 B3 C3 D3 E3

= Database disk module