3 greater than, 3 greater than (>) – HEIDENHAIN TNC 335 Technical Manual User Manual

Page 444

Advertising
background image


8/95

TNC 360

3 Commands

7-65

3.5.3 GREATER THAN (>)

>

Abbreviation for the PLC Editor:

> (GREATER THAN)

Byte/Word/Double

Constant

Execution time [µs]

1.8 to 2.4

2.0

Number of bytes

6

8

Operands: B, W, D, K

Operation:
With this command, a direct transfer from Word to Logic processing occurs. The contents of the
Word Accumulator are compared with the contents of the addressed operand. If the Word
Accumulator is greater than the operand, the condition is true and the Logic Accumulator is set to 1.
If the Word Accumulator is less than or equal to the operand, the Logic Accumulator is set to 0. The
comparison takes place over the number of bits in the operand, i.e. B = 8 bit, W = 16 bit and D = K
= 32 bit.

Example:
A constant is to be compared with the contents of Doubleword D8. The result is then assigned to
Marker M500.

Initial state:

Constant

= 16 000

Doubleword D8 = 15 000

The Accumulator and operand contents are shown in decimal notation. The 10 bit wide Accumulator
allows the entry of the highest possible Accumulator contents (2 147 483 647).

Line Instruction

Accumulator Contents

Operand Contents

x

x x x

x x x

x x x

1

L K16000

1 6

0 0 0

Bit

31

.

.

.

7

0

1

> D8

... x x x x x x 1 x x x x x x x

1 5

0 0 0

2

= M500

... x x x x x x 1 x x x x x x x

1

Line 1:

The constant is loaded into the Accumulator

Line 2:

The contents of the Accumulator and the Operand are compared (Accumulator
> Operand ? ). As this condition is fulfilled the Logic Accumulator is set to 1.

Line 3:

The contents of the Logic Accumulator (The result of the comparison) are
assigned to Marker M500.

Advertising