HEIDENHAIN TNC 335 Technical Manual User Manual

Page 5

Advertising
background image


1-2

TNC 360

Update Information No. 8

4/96

MP7670

Interpolation factor for handwheel

Input:

0 to 10

MP7670.0

Interpolation factor for low speed

MP7670.1

Interpolation factor for medium speed

MP7670.2

Interpolation factor for high speed

MP7671

Manual feed rate in "handwheel" operating mode with HR 410

Input:

0 to 1000 [% to MP1020]

MP7670.0

Low speed

MP7670.1

Medium speed

MP7670.2

High speed

A dummy plug (Id.-Nr. 271 958 03) is available for an EMERGENCY STOP.
There are connecting terminals on the adapter for the contacts from the emergency stop button
and the permissive buttons (maximum load 1.2 A)

Connector layout:

VL ID number 281 429..

KA ID number 296 466..

VB ID number 296 467 05

HR 410

ID number

296 469 01

D-sub

connector

(male

)

9-pin

D-sub

connector

(female

)

9-pin

D-sub

connector

(male

)

9-pin

Coupling on

mounting

base

(female)

18-pin

Connecto

r (male

)

18-pin

Connecto

r (female)

18-pin

Connecto

r (male)

18-pin

Housing

Shield

Housing

Housing

Shield

Housing

Housing

Shield

Housing

Housing

Shield

2

White

2

2

White

E

E

White

E

E

4

Brown

4

4

Brown

D

D

Brown

D

D

6

Yellow

6

6

Yellow

B

B

Yellow

B

B

7

Gray

7

7

Gray

A

A

Gray

A

A

8

Green

8

8

Green

C

C

Green

C

C

6

6

WH/BK

6

6

7

7

YL/BK

7

7

5

5

WH/RD

5

5

4

4

WH/BL

4

4

2

2

WH/GN

2

2

3

3

WH/YL

3

3

1

1

WH/BR

1

1

WH/BR

3

Contacts 1 + 2

WH/YL

2

Contact 2 (left) Permissive button

WH/GN

1

Contact 1 (right)

WH/BL

1

Contact 1

WH/RD

2

Contact 1 Emergency stop

YL/BK

3

Contact 2

WH/BK

4

Contact 2

Advertising